Отказ от встраивания диска в рейд, со ссылкой на другой диск. Логический диск degraded.
Конфигурация SupermicroP4DP6/DualXeon2800/8Gb/15x146Gb Seagate ST3146807LC SCSI/RAID-5 на Infortrend Sentinel SR2500.
Файловый сервер на Windows 2003. За 5 лет работы замена двух дисков на новые. Дефрагментация и бэкап по расписанию.
event.log
932," 10/26/2009 16:31:19 Chl: 0 Id: 3 SCSI Target Select Timeout"
933," 10/26/2009 16:31:19 Chl: 0 Id: 3 SCSI Drive Failure in Logical Drive 72FEFBB1"
934," 10/26/2009 16:31:19 Chl: 0 Id: 0 SCSI Bus Reset Issued"
935," 10/26/2009 16:31:19 Chl: 0 Id: 3 SCSI Target Timed Out"
936," 10/26/2009 16:31:19 Chl: 0 Id: 0 SCSI Bus Reset Issued"
937," 10/26/2009 16:31:19 Chl: 0 Id: 3 SCSI Target Phase/Signal Error"
938," 10/27/2009 13:26:55 Chl: 0 Id: 3 Scan Successful"
939," 10/27/2009 13:26:55 Rebuild Initiated - Logical Drive 72FEFBB1"
940," 10/27/2009 14:27:57 Chl: 0 Id: 1 SCSI Target Media Error - Block: 43242974"
941," 10/27/2009 14:27:57 Rebuild Failed - Logical Drive 72FEFBB1"
Далее диск ID3 метится как used, обращения к нему нет.
На контроллере ID1 Bad block encountered>Enter>Ready
Я понимаю что для встраивания ID3 требуются данные с ID1, которые повреждены.
Как проверить и восстановить ID1. Есть ли решение?